Linking clinical Data to Administrative Data
Linking Clinical Data to Administrative Data
AHRQ Contract with MHA Data Collection & Transmission
Linda Hyde RHIA, Cardinal Health, Director Research Operations
January 15, 2008
Minnesota Hospital Association Logo
Michael Pine Associates Logo
CardinalHealth Logo
Data Collection & Transmission
- Data Sources
- Classifications
- Data Merging/Linkage
- Data Editing and Validation
- Data Systems Survey
Data Sources
- UB04
- Provides patient demographic, admission and diagnostic/procedure data
- Includes new Present on Admission indicator for diagnosis codes
- Laboratory Results
- Date, time, test ID, results for selected blood gas, chemistry and hematology tests
- HL7 format preferable
Example Lab Test - HL7
Barcode example
- Billing Number V00000303073
- MRN M000279793
- Date Collected 20070101
- Time Collected 2314
- Test ID WBC
- Result 15.6
- Ref Range 4.2-10.2
Classifications/Coding
- UB04 - UB standard codes for point of origin, discharge status
- UB04 - ICD-9-CM for diagnosis and procedures
- Laboratory - Logical Observation Identifiers Names and Codes (LOINC®)
- Created and maintained by Regenstrief Institute
- In public domain
- Assign unique code for test, method, unit of measure
- Requires mapping with hospital test ID unless hospital is already
using the LOINC® codes in their laboratory system
- HL7 provides mechanism to send and identify hospital specific
and/or universal codes in their file structure
LOINC® Examples
- Blood Gas
- pCO2 Arterial (mmHg) 2019-8
- PCO2 Venous (mmHg) 2021-4
- Chemistry
- Calcium Serum (mg/dL) 17861-6
- Calcium Serum (mEq/L) 2000-8
- Protein Serum (g/dL) 2885-2
- Protein Serum (g/L) 2885-2
- Hematology
- Hematocrit (%) 20570-8
- WBC (10ˆ9/L) 26464-8
- WBC (mm3) 26464-8
Selection of Laboratory Tests
- Identify those that meet needs of the project
- Focus on common tests that have few issue regarding interpretation and provide important information on patient risk
- Marginal cost of adding new tests is relatively small
- Evaluate needs of project for culture results data and ability to easily capture from various systems
- Work with LOINC® developers for any issues requiring modification or addition of codes
Data Merging/Linkage
- Linkage of UB 04 and Laboratory Results
- Requires sufficient identifying information in both systems for both patient and specific admission
- Linkage Options
- At hospital site prior to transmission
- After transmission to host system
- Data merging will create unified database for analysis
Linkage Issues
- Format of patient identifiers between systems
- Use of patient account numbers for laboratory tests done in ED or prior to admission
- Unmatched data between systems (e.g. UB record but no laboratory data) will need to be evaluated to determine completeness of record or problems with matching process
Data Editing and Validation
- Screen for inconsistent and implausible data elements
- Individual record issues
- Frequency/trend inconsistencies
- Use laboratory data where possible to assist in screening (diagnosis codes versus laboratory values)
- Correct errors where possible and flag questionable data where correction not feasible
- Document methods to develop protocols for sharing with other partners
Data Systems Survey
- Develop survey to address key elements for data collection and transmission
- Data systems (vendors, versions)
- HL7 capabilities
- IT support
- Availability of data elements (e.g. POA indicator for non-Medicare cases)
- Availability of LOINC® codes for laboratory data